LM-068 SF6 Infrared Leak Detector
Quantitative Leak Detection • Real-time Display
Measurement Principle: Infrared (NDIR)
Measurement Range: Standard: (0-1000) ppm; High-sensitivity: (0-50) ppm
Sensitivity: Standard: 0.1 ppm; High-sensitivity: 0.01 ppm
Accuracy: Standard: 1 ppm; High-sensitivity: 0.1 ppm
Sampling Method: Pump suction
Response Time: (1-5) s
Product Introduction
The LM-068 SF6 Infrared Leak Detector adopts a high-performance microcontroller and imported infrared sensors, and uses a unique data processing method to compensate and adjust the collected data, and real-time displays the SF₆ leakage situation. It has many advantages such as high sensitivity, good stability, rapid response, automatic zero drift correction, and audible and visual alarms. It is a special product for quantitatively detecting and alarming SF₆ gas leaks in power equipment such as GIS and ring main units that use SF₆ gas as an insulating medium (non-explosion-proof product).
Main Features
1. The LM-068 SF6 Infrared Leak Detector uses the principle of infrared absorption spectroscopy to detect the content of SF₆ gas in the environment. The measurement units are ppm and g/y.
2. This model of SF6 infrared leak detector adopts an OLED display, which is self-luminous, has low power consumption, high brightness, and no viewing angle problems.
3. The sensor has a long service life, good stability, and rapid response.
4. This SF6 infrared leak detector has an audible and visual alarm function.
5. It is designed as a handheld device, with an aesthetically pleasing appearance, and the whole machine is lightweight and easy to carry.
6. The LM-068 SF6 Infrared Leak Detector can automatically or manually store measurement data.
7. It is powered by a single lithium battery and can be charged using a USB or an AC adapter.
Product Parameters
Parameter Name |
Parameter Value |
Detection Principle |
Infrared (NDIR) |
Measurement Range |
Standard: (0~1000) ppm; High-Sensitivity: (0~50) ppm |
Sensitivity |
Standard: 0.1 ppm; High-Sensitivity: 0.01 ppm |
Accuracy |
Standard: 1 ppm; High-Sensitivity: 0.1 ppm |
Sampling Method |
Pump suction |
Operating Temperature |
(-20~60)°C |
Power Supply |
4.2V DC, 2200mAh Li-ion battery |
Response Time |
(1~5) s |
Warm-up Time |
100 s |
Probe Length |
22 cm |
Service Life |
>10 years |
Calibration Interval |
Every 6 months |
Alarm Method |
Audible & visual |