Suspendisse interdum consectetur libero id. Fermentum leo vel orci porta non. Euismod viverra nibh cras pulvinar suspen.

Get In Touch

RA912F Returnable SF6 Gas Analyzer

You are here: Home » Product Center » Monitoring Instruments And Gas Sensors » RA912F Returnable SF6 Gas Analyzer

RA912F Returnable SF6 Gas Analyzer

Zero-loss Detection • Eco-friendly


SF₆ Purity

Measurement Principle: Thermal Conductivity

Measurement Range: (0~100)%

Maximum Permissible Error: ±0.5%

Response Time: ≤60 s



Product Introduction

The RA912F returnable SF6 gas analyzer is a comprehensive gas analyzer that can detect the purity, humidity, and decomposition products (SO₂, CO, H₂S) of SF6 gas, and also has the functions of gas refilling and recovery. It can recycle the detected gas to an external temporary storage container or directly refill the gas into the sampling gas chamber, achieving the goal of zero loss and zero pollution of the gas source.

Main Features

1. The RA912F returnable SF6 gas analyzer is equipped with a one – key automatic measurement function, and the system automatically locks the measurement data.

2. It has the functions of recovery and refilling, with zero emission of SF6 gas.

3. The expert diagnostic system of the RA912F returnable SF6 gas analyzer judges whether the measurement data meets the requirements according to the selected standard.

4. With a unique design, the module can be repaired or replaced.

5. The RA912F returnable SF6 gas analyzer has a large – capacity storage function (up to 10,000 entries), and the stored data can be exported via USB.

6. It is designed in a trolley – case style, with mobile wheels at the bottom, which is convenient for moving.

Product Parameters

Parameter

Value

Input Pressure Range

(0.4~2) MPa

Refill Pressure

≤0.8 MPa (direct to pressure switch)

Recovery Pressure

≤0.8 MPa (to external cylinder/bag, optional)

Exhaust Pressure

Atmospheric (recovery bag optional)

Flow Rate

100~300 mL/min (default 150 mL/min, configurable)

SF₆ Purity

Principle

Thermal conductivity

Range

(0~100) %

Maximum Permissible Error

±0.5

Response Time

≤60s

Humidity (Optional)

Principle

Laser

Capacitive

Range

(-60~+20) ℃

(-60~+20) ℃

Maximum Permissible Error

(-50~+20) ℃: ±1℃(-60~-50) ℃: ±2℃

±2℃

Response Time

≤30s

≤3min

SO₂ Detection

Principle

Electrochemical

Range

(0~100) μL/L

Maximum Permissible Error

(0~10) μL/L: ±0.5μL/L,(10~100) μL/L: ±5%

Response Time

≤60s

H₂S Detection

Principle

Electrochemical

Range

(0~100) μL/L

Maximum Permissible Error

(0~10) μL/L: ±0.5μL/L,(10~100) μL/L: ±5%

Response Time

≤60s

CO Detection

Principle

Electrochemical

Range

(0~500) μL/L

Maximum Permissible Error

(0~50) μL/L: ±2μL/L,(50~500) μL/L: ±5%

Response Time